1.DESCRIPTION

RCF Structural Epoxy Injection Resin is a two-component, 100% solids, moisture-insensitive, ultra-low viscosity, high strength, high
modulus, multi-purpose liquid epoxy adhesive. It meets the current ASTM C881 and AASHTO M235, Type I, II, IV & V Grade 2, Classes B
& C specifications.

2. WHERE TO USE

Use RCF Structural Epoxy Injection Resinfor pressure-injection of hairline cracks in structural concrete, masonry, etc. can also be used
for delamination injection, gravity feed filling of cracks in horizontal concrete and masonry. It is useful as an epoxy resin binder for
epoxy mortar patching and overlay of interior, horizontal surfaces.

3. ADVANTAGES

• Structurally restores integrity of concrete
• Ultra low viscosity for deep penetration
• High strength, high modules structural adhesive
• Convenient 1:1 mix ratio by volume
• Moisture tolerant
• Made in America
• Solvent free

4. SHELF LIFE / STORAGE

24 month shelf life when stored in unopened containers in dry conditions and stored at 40°F-95°F (4°C-35°C)

5. TECHNICAL DATA

Data list Value
Storage Conditions 40˚F – 95˚F (5˚C – 35˚C).
Condition material to 65˚F – 85˚F (18˚C – 29˚C) before using.
Mix Ratio 2:1 by volume
Viscosity 100-500 cps
Gel Time (60 g mass) 45 minutes
Tack Free Time (730F or 230C) 3 to 5 hours
Tensile Properties (ASTM D638), 7 day cure
Tensile Strength:
Tensile Elongation:
10,000 psi (67.0 MPa)
1.2%
Bond Strength (ASTM C882)
2 day cure:
14 day cure:
2,100 psi (14.5MPa)
2,200 psi (15.2 MPa)
Compressive Properties (ASTM D695), 7 day cure
Compressive Strength:
Compressive Modulus:
11,000 psi (75.9 MPa
300,000 psi (2,070 MPa
Shear Strength (ASTM D732) 6,000 psi (41.4 MPa)
Flexural Strength (ASTM D790) 7,500 psi (51.7 MPa
Shrinkage on Cure (ASTM D2566) .001
Thermal Compatibility (ASTM C884) Pass
Heat Deflection Temperature (ASTM D648) 123˚F (50˚C)
Water Absorption (ASTM D570) 0.3% (24 hr)

*NOTE: Epoxy cure is affected by temperature. Low
temperatures will increase cure time, higher temperatures
with decrease cure time.

6. APPLICATION

To pressure inject cracks:

Dispense product thru an appropriate static mixing nozzel into injection ports

To Gravity feed cracks:

Blow v-notched crack with oil-free compressed air. Seal underside if cracks reflect through. Pour or
dispense mixed epoxy into cracks. Repeat until completely filled.

To patch and grout:

Prime substrate with mixed epoxy. Place epoxy mortar using trowels before primer becomes
tack-free.

7. CONDITION PRODUCT

Condition cartridge and contents to a temperature of 65°F to 85°F (18’C – 29’C) for easier dispensing.

8. LIMITATIONS & WARNINGS

Substrate and ambient air temperature between 50°F and 100°F ( 6°C and 38°C) to be maintained thru the curing period

9. MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS

For complete installation instructions on various applications using RCF Structural Epoxy Injection Resin visit www.rhinocarbonfiber.com or call Rhino Products for more information at 1-888-684-3889.

10. CLEAN UP

Clean tools and equipment with Tough Wipes by Rhino, a biodegradable formula that removes and neutralizes the epoxy. Do not allow
epoxy to harden on equipment as cured material can only be removed mechanically.

11. SAFETY

Please refer to the SDS for RCF Structural Epoxy Injection Resin published on our Website, www.rhinocarbonfiber.com or call Rhino
Products for more information at 1-888-684-3889. This TDS sheet is not intended to list all Safety and Health Requirements necessary
for the installation of these products. All Health and Safety Requirements required by OSHA shall be followed.

12. WARRANTY

Rhino Products warrants to the Buyer that this product is in good quality and conforms to the manufacturer’s specifications in force on
the date of manufacturer and when used in accordance with the Installation Instructions and when stored as directed in the technical literature.

 

The manufacturer cannot warrant or guarantee any particular method of use, performance or application under any particular condition
and Buyer is responsible for determining the suitability of intended purpose and assumes all risks therein. RCF shall not be liable for any
injury, loss, cost of labor or consequential damages either directly, indirectly or incidentally, arising out of the use or misuse of any
product sold by RCF or another distributor. If the product is proven to be in nonconformance, the Buyers sole remedy shall be a refund
of the purchase price or replacement of the product.

Download pdf