1.DESCRIPTION

RCF High Strength Anchoring Epoxy Paste is a two-component, 100% solids, moisture-insensitive, high strength, high modulus,
multi-purpose liquid epoxy gel adhesive. It meets the current ASTM C881 and AASHTO M235 Types I, II, IV & V Grade 3, Classes B & C
specifications. It has passed 4 million cycles of simulated seismic tension test.

2. WHERE TO USE

Use RCF High Strength Anchoring Epoxy Paste as an adhesive for setting/bonding subsurface or external reinforcements to concrete
masonry or other substrates. It can also be used for reinforcing steel dowels, threaded rods, bolts, and inserts into existing concrete.
Use as a multipurpose bond adhesive for structural bonding fresh or hardened concrete to hardened concrete, sealing cracks, setting
Rhino injection ports prior to injection grouting, and as a pick-proof sealant.

3. ADVANTAGES

• Moisture tolerant
• Rapid cure formula
• High strength, high modules structural adhesive
• Agency Independent testing lab certification
• Made in America
• Solvent free
• Convenient 1:1 mix ratio by volume
• No-sag gel consistency

4. SHELF LIFE / STORAGE

24 month shelf life when stored in unopened containers in dry conditions and stored at 40°F-95°F (4°C-35°C)

5. TECHNICAL DATA

RCF High Strength Anchoring Epoxy Paste Technical Data
Storage Conditions 40˚F – 95˚F (4˚C – 35˚C).
Condition material to 65˚F – 85˚F (18˚C – 29˚C) before using.
Mix Ratio 1:1 by volume
Viscosity ¼ inch no-sag gel
Gel Time (60 g mass) 10 minutes
Tack Free Time (73’F or 23’C) 2 to 3 hours
Tensile Properties (ASTM D638), 7 day cure
Tensile Strength:
Tensile Elongation:
7,500 psi (51.7 MPa)
1.2%
Bond Strength (ASTM C882)
1 day cure:
7 day cure:
2,000 psi (13.8 MPa)
2,500 psi (17.2 MPa)
Compressive Properties (ASTM D695), 7 day cure
Compressive Strength:
Compressive Modulus:
12,500 psi (86.2 MPa)
300,000 psi (2,070 MPa)
Shear Strength (ASTM D732) 2,800 psi (19.3 MPa)
Shrinkage on Cure (ASTM D2566) 0.001
Thermal Compatibility (ASTM C884) Pass
Heat Deflection Temperature (ASTM D648) 140˚F (60˚C)
Water Absorption (ASTM D570) 0.1% (24 hr)

*NOTE: Epoxy cure is affected by temperature. Low
temperatures will increase cure time, higher temperatures
with decrease cure time.

 

Cartridge size :21.5 oz (600 ml)
Bulk sizes: 2 Gallon Units
10 Gallon Units

6. CONDITION PRODUCT

Condition cartridge and contents to a temperature of 65°F to 95°F (18’C – 35’C) for easier dispensing.

7. LIMITATIONS & WARNINGS

The minimum substrate temperature is 40˚F (5˚C). Do not thin. Solvents will prevent proper cure

8. MANUFACTURER’S PRINTED INSTALLATION INSTRUCTIONS

For complete installation instructions on various applications using RCF High Strength Anchoring Epoxy Paste visit www.rhinocarbonfiber.com or call Rhino Products for more information at 1-888-684-3889.

9. SURFACE PREPARATION

RCF High Strength Anchoring Epoxy Paste is an ideal bonding agent for multiple surfaces including concrete, brick, stone, block, and
metal. Surfaces must be clean and profiled or textured. New concrete must be a minimum of 28 days old. All dirt, oil, debris, wax, grease
or dust must be removed. Prepare the surface mechanically using a scarifier, sandblast, shot blast, bush hammer or other equipment
that will give the surface profile needed for the application. A roughened surface that exposes the aggregate and/or pores of the
substrate is imperative for good adhesion.

10. CLEAN UP

Clean tools and equipment with Tough Wipes by Rhino, a biodegradable formula, that removes and neutralizes the epoxy. Do not allow
epoxy to harden on equipment as cured material can only be removed mechanically.

11. SAFETY

Please refer to the SDS for RCF High Strength Anchoring Epoxy Paste published on our Website, www.rhinocarbonfiber.com or call
Rhino Products for more information at 1-888-684-3889. This TDS sheet is not intended to list all Safety and Health Requirements
necessary for the installation of these products. All Health and Safety Requirements required by OSHA shall be followed.

12. WARRANTY

Rhino Products warrants to the Buyer that this product is in good quality and conforms to the manufacturer’s specifications in force on
the date of manufacture when used in accordance with the Installation Instructions and when stored as directed in the technical
literature.

The manufacturer cannot warrant or guarantee any particular method of use, performance or application under any particular condition
and Buyer is responsible for determining the suitability of intended purpose and assumes all risks therein. RCF shall not be liable for any
injury, loss, cost of labor or consequential damages either directly, indirectly or incidentally, arising out of the use or misuse of any
product sold by RCF or another distributor. If the product is proven to be in non-conformance, the Buyers sole remedy shall be a refund
of the purchase price or replacement of the product.

Download pdf